PARAMETER
VALUE
StoP
no
ProS
invE
Fot1
no
AP.Ch
PrES
Fot2
CFCh
Ch
no
Ft.tE
no
Si
CoS1
no
AP
APCh
FirE
CoS2
no
APCh
Ch
DESCRIPTION

STOP INPUT

The input STOP is not available (ignored by the control unit)
The input STOP stops the gate: pressing the command START the gate
continues the motion
The command STOP stops the gate: at the next START the gate starts
moving in the opposite direction
Photocell 1 input
This menu allows enabling the input for type 1 photocells, that is to say,
photocells active both during the opening and closing phase
Input disabled (ignored by the control unit)
Input enabled
If the photocells are activated, the gate opens and remains open until
deactivated
Photocell 2 input
This menu allows enabling the input for type 2 photocells, that is to say,
photocells non active during the opening phase
Input enabled even at standstill gate too: the opening movement does not
start if photocell is interrupte
Input enabled for the closing phase only
WARNING: if you select this option, you must disable photocell test
Input disabled (ignored by the control unit)
Test of the photocells
Function deactivated
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second.
Safety ribbon 1 input
This menu allows enabling the input for type 1 safety ribbon, that is to say,
fixed ribbons
Input disabled (ignored by the control unit)
Input enabled during the opening and disabled during the closure
Input enabled in opening and closure
If the input is activated, the gate opens. To close the gate the input must
be deactivated and a command must be sent to start the maneuver
(automatic closing does not work).
Safety ribbon 2 input
This menu allows enabling the input for type 2 safety ribbon, that is to say
mobile ribbons
Input disabled (ignored by the control unit)
Input enabled in opening and closure
Input enabled during closure and disabled during opening
- 53 -
DEFAULT
MEMO
no
no
CFCh
no
no
no