V2 AYROS 800-230V Bedienungsanleitung Seite 54

Elektromechanischer irreversibler schiebetorantrieb 230v fuer tore bis 1200 kg gewicht
Vorschau ausblenden Andere Handbücher für AYROS 800-230V:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 154
PARAMETER
VALUE
Ch.AU
no
0.5" - 20.0'
Ch.tr
no
0.5" - 20.0'
PA.t r
Si
no
LUCi
t .LUC
no
CiCL
AUS
t iM
biSt
Mon
LP.PA
no
Si
Strt
StAn
no
AP.Ch
PrES
oroL
DESCRIPTION
Automatic closing
In automatic mode, the control unit automatically recloses the gate on
expiry of the time limit set in this menu
Function deactivated
The gate recloses after the set time
(adjustable time from 0,5" to 20.0')
Closure after passage
During the automatic operation, the pause count down starts from the set
up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing as soon as transit through the
gate is completed, therefore, a time shorter than
Function deactivated
The gate recloses after the set time
(adjustable time from 0,5" to 20.0')
Pause after transit
In order to let the gate open for the shortest possible time, it is possible
to stop the gate once the passage before the photocells is detected.
If the automatic working is enabled, the time of the pause is
Function deactivated
Courtesy lights
This menu allows setting the automatic operating of the courtesy lights
during the opening cycle of the gate
Timed function (from 0 to 20')
Function deactivated
On for the entire duration of the cycle
Auxiliary channel
This menu allows setting the operating of the relay of the lighting of the
courtesy lights by means of a remote control stored on the channel 4 of
the receiver
Timed function (from 0 to 20')
Bistable operation
Monostable operation
Blinker during pause time
Function deactivated
The blinker will be on during the pause time too (gate open with
automatic closure active)
Activation inputs function
This menu allows selecting input operation modes (see chapter 4.4)
Standard mode
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode
Open/Close command
Manned operation
Timer mode
Ch.AU
is generally used
StAn
- 52 -
DEFAULT
MEMO
no
no
no
Ch.tr
t.LUC
1 '00
Mon
no
StAn