Technical Data - Hilti NURON TE 2-22 Original Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
3.4.2 Indicators showing the battery's state of health
To check the battery's state of health, press the release button and hold it
down for longer than three seconds. The system does not detect a potential
malfunction of the battery due to misuse, for example battery dropped or
pierced, external heat damage, etc.
Status
All LEDs show in sequence, fol-
lowed by one (1) LED showing con-
stantly green.
All LEDs show in sequence, fol-
lowed by one (1) LED quick-flashing
yellow.
All LEDs show in sequence, fol-
lowed by one (1) LED showing con-
stantly red.
4

Technical data

Weight in accordance with EPTA Procedure 01,
without battery
Single impact energy in accordance with EPTA pro-
cedure 05
Drilling diameter range in concrete/masonry (ham-
mer drilling)
Ambient temperature for operation
Storage temperature
4.1 Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
*2266024*
Meaning
The battery can remain in use.
The check to ascertain the battery's
state of health did not complete.
Repeat the procedure, or consult
Hilti Service.
If a connected product can still be
used, the remaining battery capac-
ity is below 50 %.
If a connected product can no
longer be used, the battery has
reached the end of its useful life
and has to be replaced. Consult
Hilti Service.
2266024
2.3 kg
1.5 J
4 mm ... 16 mm
−17 ℃ ... 60 ℃
−20 ℃ ... 70 ℃
21.6 V
See the end of
these operating
instructions
−17 ℃ ... 60 ℃
−20 ℃ ... 40 ℃
−10 ℃ ... 45 ℃