Electrical installation:
Connect the controls according to the following instructions for electrical installation (Fig. 5).
Fig. 5
Connecting the evaporator:
To connect the evaporator (Bi-O) a suitable silicone cable of 1.5 mm² is required.
Attention: Take care that the terminal L1 (Bi-O) is correctly connected to the evaporator Wb (also named
W1 with some heaters). The controls detect the low water level of the evaporator. Therefore, connect the
low water level Wm (this terminal is also named P (Protect) with some sauna heaters).
Attention: The power unit must be installed by an authorised electrician only, under observation of the
relevant guidelines.
All electrical connection cables installed inside the sauna cabin must be suitable for an ambient
temperature of at least 170 °C. Furthermore, the controls must be connected to a fixed mains outlet only.
EN
Note: If a preselection function or remote start is used, a door contact switch or disconnecting rocker
(cover protection system) must be used according to the standards EN 60335-1 or EN 60335-2-53.
This door contact switch or disconnecting rocker is connected to the terminal "rocker/door" (if both are
used, they must be connected in series).
Opening the sauna door or pressing the disconnecting rocker during the enabled preselection function will
deactivate preselection (according to the standards EN 60335-1 and EN 60335-2-53).
In order to use the preselection function again after opening the door or pressing the disconnecting rocker,
it must be activated again.