Adjusting the feet
CAUTION:
The feet must never be removed. Do not restrict the
floor clearance through carpets, strips of wood or
similar. Danger of heat accumulation!
 Use the delivered wrench to loosen the lock nuts.
 Rotate the feet to change the height.
 Tighten the lock nuts, if the unit is aligned. The
feet must have solid ground contact.
 Check with a spirit level whether the appliance is
leveled horizontally. If the unit is not in balance,
the feet must be adjusted again.
Water connection
CAUTION:
 The Installation of the water supply must conform
to the local laws and regulations.
 The appliance is not suitable for hot water supply.
 Use the new supplied hose set to connect the
appliance to the water supply. Do not reuse old or
used connection sets.
 If the water pipe is new or long time not used,
ensure before connecting to the water system,
that the water is clear and free from contamina-
tion.
Notes on inlet hose safety system (delivery scope
depending on model)
The safety system consists of a double-walled inlet
hose. It guarantees to cut off the water supply when
leakage of the inner hose. Switching off the water
supply leads over an electronic contact.
If necessary, you can order an inlet hose safety sys-
tem from your dealer or in our online accessories
shop, www.bomann-germarny.de. To order, use the
reference number found under "Technical Data".
Connect the water inlet hose (cold water connection)
NOTE:
The water pressure must be between 0.1-1.0 MPa.
With higher pressure: use a pressure regulator.
 Connect the water inlet hose to a water thread
with ¾". Screw the hose firmly in the direction of
the screw thread; pay attention for a tight fit.
 Connect the other end of the inlet hose to the inlet
valve on the appliance back; pay attention for a
tight fit too.
Connect the water drain hose
NOTE:
The drain hose has a length of approx. 1.5 m and
can extend with a suitable hose and connecting
piece to a length of max. 4 m.
CAUTION:
In order to prevent backflow of contaminated water,
the free end of the hose must not come under the
water level of the drain.
 Connect the drain hose to a drain pipe with a
minimum diameter of 40 mm; alternatively, the
drain hose can be fixed to a sink or directly to the
drainage.
 Always make sure that the hose is not bent or
squeezed. For this purpose, use the supplied
hose retaining sheet (a).
 The hose must be installed at a height of min.