Herunterladen Inhalt Inhalt Diese Seite drucken

Haier WS120GA Bedienungsanleitung Seite 26

Vorschau ausblenden Andere Handbücher für WS120GA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Troubleshooting
of a problem please check all shown possibilities and follow below instructions before you
contact an after sales service. See CUSTOMER SERVICE.
WARNING!
Before maintenance, deactivate the appliance and disconnect the mains plug from
the mains socket.
improper repairs can cause considerable consequential damages.
A damaged supply should only be replaced by the manufacturer, its service agent or
Error Code
Cause
H1
The appliance gives a high-temper-
ature warning when the upper com-
partment's temperature has been
higher than 25 °C for 3 hours.
L1
The compressor stops working when
the temperature is lower than 0 °C.
The low temperature warning is given
when the temperature has been lower
than 0 °C for 2 hours.
22
Solution
Ambient temperature is too high.
The appliance working tempera
ture should be between 10°C and
38 °C.
Ambient temperature is too low.
The appliance working tempera-
ture should be between 10 °C and
38 °C.