ATTENTION: If the water quantity is left at zero '0' litres, the option will be DISABLED.
Lastly, press the MENU button to exit the TECHNICAL MENU.
2.10.- DISPLAY ALARM SIGNALS
A. MAXIMUM FILLING TIME FOR BOILER WATER
When a time set by the manufacturer is exceeded, the display will show:
At the same time, the button LEDs begin to fl ash.
To cancel the alarm, the main switch must be set to 0 and then to 1.
B. MAXIMUM BOILER TEMPERATURE
The display will show the boiler temperature alarm when it exceeds 140ºC for more than 5 seconds.
The alarm will disappear when the boiler temperature returns to its normal values.
C. INTERRUPTED TEMPERATURE SENSOR
-
The alarm will disappear when the boiler temperature is once again at an acceptable value.
-
This situation is due to an incorrect selection on the heating menu (reprogram the control unit). (SEE PROGRAMMING
IN SECTION 2.9.5, HEATING MENU OPTION.)
In order to eliminate this alarm:
Press the MENU button until the following appears (even if the message 'Probe Unconnect') appears, do not stop
pressing MENU):
Press the MENU button repeatedly to go through various options until you see the following on the display:
Page 58
Downloaded from
www.Manualslib.com
When the sensor detects a temperature of 0ºC for 5 seconds, the LEDs on the button pads will
fl ash and the display will show:
In the case of the control unit being replaced, a machine with a display and pressure switch will
display:
with pump / without pump
manuals search engine
Off
hh.mm
Time-out alarm
Boiler fi llingUp
Alarm
Boiler temp.
T.ProbeUnconnect
T.ProbeUnconnect
Language
xxxxxx
Mixed tea
INSTALLATION AND OPERATION MANUAL