INSTALLATION
Installing/Replacing the lamp
For the installation, you need one CDM-T 150W G-12 lamp.
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp or check the operating hour meter regularly and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1: Open the lampholder cover by loosening the fixation screw.
Step 2: If replacing the lamp, remove the old lamp from the spot.
Step 3: Insert the lamp in the lampholder.
Step 4: Insert the lampholder and close the device.
Installing/Replacing the lens
The lenses should be inserted with the bulge facing outwards. This will ensure the following properties:
1. The mounting clamp for the lenses engages with the groove on the lens and in this way prevents the
unintentional falling out of the lens.
2. The lens has a filter function with regard to the infrared constituent in light. The reflective effect towards
the housing rear panel can only function if the lens has been installed correctly.
Before replacing the lens, remove the color filter frame. Press the holding clip and carefully let the lens fall
forward.
Please note: Before operating the device, a lens must be installed due to safety-related requirements.
Please use this device only with installed color filter frames!
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened housing!
16/20
00107504, Version 2.2