Herunterladen Inhalt Inhalt Diese Seite drucken

Assembly Diagram - Palazzetti INSERIMENTO A70 Installations, Bedienungs Und Wartungsanleitungen

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 48

6.3 ASSEMBLY DIAGRAM

(Fig. 6.3)
A) For proper installation, the smoke ducting between the
fireplace and the flue must have all joints sealed.
B) Rear external air intake, ensure a minimum distance of 5
cm between cladding and combustion air intake pipe.
C) UNI standards require the installation of a heat recovery
grille as close as possible to the ceiling.
D) Counter-hood and fireproof load-bearing structure
E) Cladding in ceramic fibre or rock wool with external
aluminium foil
F)
Protect any wooden parts with fireproof material.
G) Min distance. 1 cm between cladding and fireplace stove
H) The cladding must be made of fireproof material
Fig. 6.3.1 In the product technical detail shows the
minimum distances in centimeters to be observed
in the placement of the fireplace with respect to
materials and combustible objects.
Leave enough room for maintenance
Assembly must be carried out by qualified
personnel.
If there are flammable materials or structures
on the back of the firebox, they must be at a
minimum distance of 10 cm.
To ensure correct installation, the smoke pipe
between the fireplace and flue must be airtight,
sealing all the joints.
If the fireplace is installed with a flue that
has already been used with other fireplaces,
it should be cleaned thoroughly to avoid
malfunctions and the danger of unburned parts
deposited on the inside from catching fire.
Improper installation may compromise the
safety of the unit.
It must be possible for qualified personnel to
access the inside of the stove when it is not in
operation.
The cladding must be in fireproof material and
it must not have any removable parts, so that
electrically powered and moving parts are not
accessible by the user.
Do not place flammable objects or materials
in the radiation area of the hearth, and in any
case not less than 1 m.
INSTALLATION
Fig. 6.3
G
H
MINIMUM DISTANCE FROM COMBUSTIBLE MATERIALS
00 4776070 - 17/12/2018 - PN - Italy
C
D
F
Z
Fig. 6.3.1
A
E
B
37