Herunterladen Inhalt Inhalt Diese Seite drucken

IFM Electronic Efector 200 Bedienungsanleitung Seite 14

Einweglichtschranke oj laser
Vorschau ausblenden Andere Handbücher für Efector 200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Setting of the sensitivity with stationary objects*
Activate the programming mode of the unit.
Press for about 2s
until the red LED flashes.
1
The red LED goes out; the yellow and green LEDs flash alternately.
The unit is in the programming mode.
Set the sensitivity with object.
2
The yellow and green LEDs go out for approx. 1s,
then flash again alternately.
Set the sensitivity without object.
3
The yellow and green LEDs go out for approx. 1s,
after approx 3s the green LED is on.
The unit is in the operating mode.
You can also proceed in reverse order: first setting without the object, then with
the object.
* The sensitivity can also be set in exactly the same way using the programming wire (pin
2 / WH). To activate the functions the programming wire is connected for the appropriate
time to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units. Feedback: If set-
ting was not successful via the programming wire, the output will switch for 2s. The unit
then reverts to the operating mode with the sensitivity unchanged.