FAULTS

The opening of the units and the replacement of the water pressure charged parts
may only be effected by authorized personal in order the ensure the unit security
and its tightness.
Help with faults:
Fault
Water flow rate falls.
Leaks in the cartridge filter with
pressure reducer.
Filter bowl becomes turbid.
Hairline cracks on the filter bowl.
Downstream pressure slowly ris-
es when no water flowing.
Downstream pressure slowly ris-
es when no water flowing.
Cause
Screen is blocked.
Cartridge filter with pressure re-
ducer has been exposed to high
temperatures or solvents.
Cartridge filter with pressure re-
ducer has been exposed to high
temperatures or solvents.
Impermissible increase in pres-
sure due to service water heating.
Wear in the pressure reducer car-
tridge.
Remedy
Replace the screen!
Inform the fitter or nearest cus-
tomer service centre!
Inform the fitter or nearest cus-
tomer service centre!
Inform the fitter or nearest cus-
tomer service centre!
Check the safety valve of the hot
water boiler!
Inform the fitter or nearest cus-
tomer service centre!
Check the safety valve of the hot
water boiler!
Inform the fitter or nearest cus-
tomer service centre!