Test Data
Commission Regulation (EC) No 1275/2008 Requirement
Mode
Ecodesign requirements, from 7 January 2013
Off mode
Power consumption in 'off mode':
Power consumption of equipment in any off-mode
condition shall not exceed 0.50 W
Standby mode
Power consumption in 'standby mode(s)':
The power consumption of equipment in any
condition providing only a reactivation function,
or providing only a reactivation function and a
mere indication of enabled reactivation function,
shall not exceed 0.50 W.
The power consumption of equipment in any
condition providing only information or status
display, or providing only a combination of reacti-
vation function and information or status display
shall not exceed 1.00 W.
Seasonal space heating energy efficiency
Description
Seasonal space heating energy efficiency in active mode-η
F(1) is a correction factor accounting for a positive contribution to the seasonal space
heating energy efficiency of electric storage local space heaters due to adjusted
contributions for options for heat storage and output; and a negative contribution
to seasonal space heating efficiency for commercial local space heaters due to
adjusted contributions for options for the heat output, expressed in %;
F(2) is a correction factor accounting for a positive contribution to the seasonal
space heating energy efficiency due to adjusted contributions of controls of indoor
heating comfort, the values of which are mutually exclusive, cannot be added to
each other, expressed in %;
F(3) is a correction factor accounting for a positive contribution to the seasonal
space heating energy efficiency due to adjusted contributions of controls for indoor
heating comfort the values of which can be added to each other, expressed in %;
F(4) is a correction factor accounting for a negative contribution to the seasonal
space heating energy efficiency by auxiliary electricity consumption, expressed in %;
F(5) is a correction factor accounting for a negative contribution to the seasonal
space heating energy efficiency by energy consumption of a permanent pilot flame,
expressed in %.
Seasonal space heating energy efficiency-η
Verdict
S,on
S
13
Result - Remark
Verdict
0
P
/
N/A
0.34
P
Value
40 %
0 %
7 %
1 %
0 %
0 %
38 %
P