Herunterladen Inhalt Inhalt Diese Seite drucken

Appliance Equipment; Installation - BOMANN DU 7605 G Bedienungsanleitung, Garantie

Haushalts- dunstabzugshaube
Vorschau ausblenden Andere Handbücher für DU 7605 G:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Appliance Equipment

Appliance overview
Delivery scope
1x aluminum grease filter, 1x 2-part chimney shaft,
1x exhaust hose, 2x non-return valve,
tion material and drilling template

Installation

The cooker hood is only intended to be installed
over a hob with no more than four hob elements
There must be a safety distance between the hot-
plate of the cooking pot on the hob and the bottom
part of the cooker hood:
The distance must be between 65 – 75 cm. For gas
appliances, the distance must be at least 65 cm. If
the installation instructions for the gas cooker specify
a greater distance, this distance must be taken into
consideration.
Selecting the fume outlet
You can operate the cooker hood in two modes:
Extraction mode
WARNING:
 The extracted air may not be vented into a flue
which is used for the waste gas from appliances
which are powered by gas or other fuels.
1 Shaft unit
2 Hood body
3 Aluminum grease filter
4 Motor unit
5 Glass cover
(grease
filter cover)
incl. Installa-
.
WARNING:
 When venting the extracted air, comply with the
regulations of the relevant local authorities.
The hood has an upper air outlet to vent cooking
odors to the outside.
The extracted air is normally vented
vertically. The extracted air can vent-
ed through the wall units and the loft
floor to the roof ridge.
If there is a conduit under the wall
units, the extraction duct can be routed
so that the extracted air can be vented
horizontally through the wall.
Recirculation mode
If you do not have a direct extraction vent to the out-
side; the hood can also work in recirculation mode
(i.e. without an extraction vent to the outside; the
filtered air is released back into the room). In this
case, activated carbon filter as described under
stalling the activated carbon filter for recirculation
mode"
, must be used.
Activated carbon filter are not supplied. You can or-
der the carbon filter from your dealer or in our online
accessories shop, www.bomann-germany.de. To
order, use the reference number found under
nical Data".
Assembly
WARNING:
 When assembling or inserting the extraction filter
as well as the carbon filter, the appliance must not
be connected to the mains.
 Failure to use the mounting fixtures may lead to a
risk of electric shock.
19
"In-
"Tech-

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

776051

Inhaltsverzeichnis