Cleaning and replacing the air filter
Please check and clean the air filter periodically. When the indicators or a
message prompts you to clean the air filter, comply with it as soon as possible.
The filter unit with 2 sheets of filters is inside of the filter cover. An extra air filter
is also attached to inner side of the filter cover. If one of the filters is damaged or
heavily soiled, replace whole filter set with a new one.
Request for a filter set with the following type number from your dealer when
purchasing a new one.
Type number : 003-004135-01
Turn the projector off, and unplug the power
1.
cord. Allow the projector to sufficiently cool
down.
Use a vacuum cleaner on and around the
2.
filter cover.
Pick and pull up the filter cover knobs to
3.
take it off.
4.
Press up slightly the bottom side knobs to
unlock the bottom side of the filter unit. Pull
the center knob to take the filter unit off.
Use a vacuum cleaner for the filter vent of
5.
the projector and the outer side of the filter
unit.
6.
The filter unit consists of two parts. Press
down around the interlocking parts to
unlock, then separate the two parts.
Use a vacuum cleaner for the inner side of
7.
each part of the filter unit to clean them up.
If the filters are damaged or heavily soiled,
replace them with the new ones.
Combine the two parts to reassemble the
8.
filter unit.
Put the filter unit back into the projector.
9.
(continued on next page)
Setup Guide
(UX38241)
7
16
2
3
Filter cover
knobs
4, 5
6
Interlocking
parts
020-000504-02 Rev. 1 (06-2012)
Filter cover
Extra
air filter
Filter unit
Filter unit
knobs

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lw401Lwu421Lx601iLw551iLwu501i

Inhaltsverzeichnis