Warning! Risk of injury from electrical
current.
• The electrical mains terminal is live.
• Make electrical mains terminal free of volt-
age.
• Loose and inappropriate plug and socket
connections can make the terminal over-
heat.
• Have the clamping connections correctly in-
stalled.
• Use strain relief clamp on cable.
• Follow the connection diagram.
Important! You must observe the minimum
distances to other appliances and furniture
cabinets or other units according to Assembly
Instruction.
If there is no oven beneath the hob insert a di-
viding panel at a minimum distance of 20 mm
from the bottom of the hob.
Protect the cut surfaces of the worktop against
moisture using a suitable sealant included in
the product in fitting bag. The sealant seals the
appliance to the work top with no gap. Do not
use silicon sealant between the appliance and
the worktop. Avoid installing the appliance
next to doors and under windows as hot cook-
ware may be knocked off the rings when doors
and windows are opened.
Only an authorized service engineer can in-
stall, connect or repair this appliance. Use only
original spare parts.
Only an authorized service engineer can in-
stall, connect or repair this appliance. Use only
original spare parts.
Electrical connection
Before connecting, check that the nominal volt-
age of the appliance stated on the rating
plate, corresponds to the available supply
voltage. Also, check the power rating of the
appliance and ensure that the wire is suitably
sized to suit the appliance power rating (refer
to the Technical data chapter).
The rating plate is located on the lower casing
of the hob.
All manuals and user guides at all-guides.com
The appliance is supplied with a connection
cable. This has to be provided with a proper
plug, able to support the load marked on the
identification plate. To connect the plug to the
cable, follow the recommendation given in fol-
lowing figure.
Replacement of the connection cable
The replacement of the connection cable re-
quires the specific equipment of a technician.
In this case, only cable type H05V2V2-F T90
must be used. The cable section must be suit-
able to the voltage and the working temper-
ature. The yellow/green earth wire
approximately 2 cm longer than the brown (or
black) phase wire
1
The plug has to be fitted in a proper socket. If
connecting the appliance directly to the elec-
tric system, it is necessary that you install a
double pole switch between the appliance
and the electricity supply, with a minimum gap
of 3 mm. between the switch contacts and of a
type suitable for the required load in compli-
ance with the current rules.
The connection cable has to be placed in order
that, in each part, it cannot reach a tempera-
ture 90 °C higher than the room temperature.
The brown (or black) phase cable (fitted in the
terminal block contact marked with "L") must
always be connected to the network phase.