Herunterladen Inhalt Inhalt Diese Seite drucken

Natural Stone Cladding; Heating; Special Information - Olsberg Antuco Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Natural Stone cladding

This natural stone cladding may not be overheat-
ed, as cracks could appear in the stone.
Use a maximum of 3 kgs wood or briquette (that
are 2 suitable logs or 1,5 briquettes) for heating.
As the cladding as a natural product comes from
a "grown" boulder, structure and colour scheme
may be very different.
The surface may be alterated under temperature
influence.
Please note before heating for the first
time
Remove all accessories from the ash pan and
combustion chamber first.
The odour given off by the evaporation of the
protective coating disappears after the stove has
been burning for several hours (ventilate the
room well).
The stove has a high quality temperature re-
sistant coat, which does not achieve its final
strength until the stove has been heated for the
first time.
- You should therefore never leave anything on
the stove and not touch the surfaces as the paint
coat could otherwise be damaged.
Igniting
Empty the ash pan if necessary and slide back
in.
Open the primary and secondary air controller.
Place and ignite the kindling materials (paper,
ignition cubes, kindling wood, etc.).
Close the door to the combustion chamber so
that the kindling material can catch fire.
As soon as the kindling material is burning well,
add a small quantity of fuel.
Using the air controller
Secondary air controller
The primary aire controller is located below the door
and the secondary air controller above the door.
Secondary air controller to the right ⇒ Open
Primary air controller pulled out
Primary air controller...
... OPEN
Ignition adjustment max. heating output
10
Primary air controller
⇒ Open
... ½ OPEN Nominal heat output with billet wood
... ½ OPEN Nominal heat output with wood
briquettes
... CLOSED glow
As the secondary air also contributes to the cleanli-
ness of the glass pane, the secondary air controller
must always be moved in the direction of the open
position while the stove is lit.
As the performance of your stove is very much de-
pendent on the chimney draught, the primary air con-
troller has to be adjusted according to your own ex-
perience. Please note that you should not use your
stove if there is not an adequate air supply (slide
valve setting too low), as this causes the emissions
to increase.

Heating

Only place the quantity of fuel required to
achieve the heating requirement.
For a nominal heating output 6 kW:
- max. 2 kg billet wood
- max. 1,8 kg wood briquettes
- max 10 Brown coal briquette
Open the combustion chamber door slowly after
adding new fuel, as otherwise the combustion
gases can escape.
Empty the ash pan or combustion chamber in
good time. Otherwise it is possible for the com-
bustion air intake to be blocked or for the grate to
be damaged.
Only remove the ash pan to empty it. Always
keep the ash door firmly shut during heating.
Clean the ash pan compartment regularly after
removing the ash pan to remove any ash that
may have been spilled (e.g. use a vacuum
cleaner).
Attention: Any stove and ash residues must
have been left to cool before being removed.
Heating during the transition period
Prerequisite for the stove to function well is the cor-
rect delivery pressure (chimney draught). This very
much depends on the external temperature. There-
fore, if the external temperatures are high (above
16°C) the delivery pressure can be disrupted.
What to do?
Open the primary air controller as far as possible.
Only put on a small quantity of fuel.
Frequently stoke the ash.

Special information

The manufacturer's guarantee expires if the stove is
significantly or permanently overloaded above the
nominal heating output, or if fuels other than those
listed are used.

Werbung

Inhaltsverzeichnis
loading