Heating

For a nominal heating output 5 kW:
- max. 1,5 kg billet wood; burning time >45 min
For max. heat output allowed:
- max. 3 kg billet wood
● Open the combustion chamber door slowly for add-
ing new fuel, as otherwise the combustion gases can
escape.
● Empty the ash pan or combustion chamber in good

Heating during the transition period

time. Otherwise it is possible for the combustion air
intake to be blocked or for the grate to be damaged.
● Only remove the ash pan to empty it.
● Clean the ash pan compartment regularly after re-
moving the ash pan to remove any ash that may
have been spilled (e.g. use a vacuum cleaner).

Cleaning

Attention:
Any stove and ash residues must have been left to
cool before being removed.
delivery pressure (chimney draught). This very much
depends on the external temperature. Therefore, if the
external temperatures are high (above 16°C) the deliv-
ery pressure can be disrupted.
What to do?
● Open the combustion air slide valve complete.
What?
inside of stove
connection piece
glass panel
painted surfaces
● Only place the quantity of fuel required to achieve
the heating requirement.
14
Prerequisite for the stove to function well is the correct
● Only put on a small quantity of fuel.
● Frequently stoke the ash.

Cladding

Special information

● The cladding may not be overheated, as cracks
could appear.
● Use a maximum of 3 kg wood for heating.
● As the natural cladding comes from a „grown" boul-
der, structure and colour scheme may be very
different.
● The surface may be altered under temperature
The manufacturer's guarantee expires if the stove is
nominal heating output, or if fuels other than those list-
ed are used.
● The stove must only be used with the combustion
chamber door shut.
proof, non-combustible container.
● Attention: The surfaces get hot! Always use the en-
closed glove when operating the stove.
● Convection air openings may not be covered.
tered. In particular, it must be ensured that any nec-
place is being used.
stove.
How often?
at least 1 x per year
at least 1 x per year
influence.
significantly or permanently overloaded above the
● Never remove hot ashes. Only store ashes in a fire-
● Never use white spirit, benzene or other inflamma-
ble, hazardous materials to ignite the fire.
● The combustion air supply fittings must never be al-
essary combustion air pies are open while the fire-
● Do not make any changes or modifications to the
as required
as required
Using what?
hand brush,
vacuum cleaner
hand brush,
vacuum cleaner
when cold
using glass cleaner for
stoves- and oven glasses
when cold
with a slightly damp microfibre cloth