Maintenance and cleaning

CAUTION
Risk of injury due to unforeseeable start-up. Internal monitoring functions can shut down the
unit and reactivate it automatically.
Disconnect the power plug before carrying out any work on the unit.
NOTE
Do not use aggressive cleaning agents or chemical solutions. These agents can damage the
housing, impair the function of the device and harm animals, plants and the environment.
Clean the unit with clean water and a soft brush or sponge wherever possible. Remove stub-
born dirt with the aid of the recommended cleaning agents.

Cleaning the unit

Clean the unit as required, but at least twice a year.
• When cleaning the pump, pay particular attention to the impeller unit and the pump casing.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
• After cleaning, thoroughly rinse all parts in clean water.
Pump disassembly/cleaning
• Pull the power plug and remove all connections.
• Dismantle the unit as shown in the figure.
• Reassemble the unit in reverse order.
• During assembly check that
– the pump is fastened in the holder.
– the power cable is guided out through the groove on the housing and is not significantly
kinked or pinched.