Herunterladen Inhalt Inhalt Diese Seite drucken

nemaxx P6 Originalbetriebsanleitung Seite 38

Freistehender pelletofen
Vorschau ausblenden Andere Handbücher für P6:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 41
Problem
6. orange and lazy fire, piled pellet,
carbon on the glass
7. The fire went out and power went
off automatically.
8. The blower still works after the
stove is cool and fuel feed stops.
9. Not enough heat wind
10. Showing „E5" on the display
EN
Reason
Lack of air intake for
burning.
The hopper is empty.
No fuel feed.
The fuel feed is too little.
Low temperature switch
(30˚C) is wrong.
Set temperature is reached
The low temperature switch
(30˚C) is broken.
Unqualified fuel
Blower speed is too low or
not running.
Heat exchange tubes or flue
pass are dirty.
Vent pipe is blocked
The door is opening or seal
needs to be replaced
The are some leakages
38
Solution
Clean the block in gate bar.
Check the door and window
glass gasket sealed or not.
Check the air intake pipe
and venting pipe blocked or
not, and clean it.
Change to the big diameter
pipes if pipes are too long to
affect combustion.
Raise the combustion fan's
speed.
Call the dealer to reset the
program
Put fuel into the hopper.
refer to (2)
Lower the speed of
combustion fan
Cool the stove at least 1
hour then operate again or
change the low temperature
switch (30˚C).
„ECO" its normal, waiting,
after the temperature is
below set on, it will auto-
matically switch on again
Change this switch.
Use the standard special pellet.
Change the blower(Broken) or
the mother board is broken
Clean the heat exchange
tubes or flue pass.
Shut down the stove, check
the venting pipe
Close the door or change the
seal. Check it and repair it.
Raise the combustion fan's
speed to offer more
pressure in the stove

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für nemaxx P6

Diese Anleitung auch für:

P9P12

Inhaltsverzeichnis