The extracted air is normally vented vertically.
The extracted air can vented through the wall
units and the loft floor to the roof ridge.
If there is a conduit under the wall units, the ex-
traction duct can be routed so that the extracted
air can be vented horizontally through the wall.
Recirculation mode
If you do not have a direct extraction vent to the out-
side; the hood can also work in recirculation mode
(i.e. without an extraction vent to the outside; the
filtered air is released back into the room). In this
case, an activated carbon filter mat as described
"Installing the activated carbon filter mat for
under
recirculation mode"
, must be used.
Activated carbon filter mat is not supplied. You can
order the carbon filter mat from your dealer or in our
online accessories shop, www.bomann-germany.de.
Use the reference number found under
Data".
Assembly
WARNING:
 When assembling or inserting the extraction filter
as well as the carbon filter, the appliance must not
be connected to the mains.
 Failure to use the mounting fixtures may lead to a
risk of electric shock.
CAUTION:
 Before mounting, check that the wall has enough
load capacity to bear the cooker hood.
 When drilling the holes in the wall always make
sure that no existing electrical cables or other ob-
jects are damaged.
 Make sure that the ventilation slots are clear of
obstacles and are not covered.
NOTE: Recommendations for preparation work
 When installing, ask another person to assist.
 Wear protective gloves to prevent injuries from
any sharp edges.
1
4
Mounting at the wall
Mounting below the wall unit
"Technical
 The hood is mounted at the wall or below a suita-
ble wall unit. Determine the position of the extrac-
tor hood centrally above the hob in conformance
with the specified safety distances.
 Remove the aluminum grease filter.
 Select the fume outlet and set the lever to the
appropriate position, see
let".
Mounting at the wall
 Mark the necessary holes for the wall mounting by
using the supplied drill template and check them
with a spirit level!
 Drill two mounting holes Ø 8 mm into the wall and
insert the dowel pins (1). Then turn in the screws
(2) so far that they project approx. 4 mm out of the
wall.
41
2
3
5
6
"Selecting the fume out-