Maintaining the BestWater System 33-00 ULTIMATE
EN
Remove
the
cartridges from the system in order.
Once the pre-fi lter cartridges have
been removed you can replace the
post-fi lter. Push the connecting rings
at the ends of the post-fi lter inward
and remove the post-fi lter. Use the
instructions and images on page 40
for assistance if necessary.
Now you can remove the post-fi lter
from its fastening clamps and install
the new post-fi lter. Remember the
direction of the water fl ow when ins-
talling the new post-fi lter. This goes
from the bottom up.
64
individual
pre-fi lter
Now connect the quick connects to
the new post-fi lter.
Once you have replaced the post-fi l-
ter, you can now install the new pre-
fi lter. Insert the pre-fi lter cartridge
with activated charcoal into the left
compartment.
Then insert the pre-fi lter cartridge
with the 20 µm pre-fi lter into the
right compartment. When screwing
in the pre-fi lter cartridges, make
sure that they are only screwed in
fi nger-tight.