7 Commissioning and operation

1 Schakel de netspanning voor het voedingsapparaat in of steek de stekker in de
wandcontactdoos.
2 Switch on the power unit by operating the on/off button.

8 Functional check

When the power unit is switched on, the indicator lamps of the switch and the high-voltage
indicator are lit.
Proper operation of the power unit can be checked on the basis of the proper operation of the
equipment connected.

9 Maintenance

Warning:
-
Disconnect the power supply before carrying out work on the unit.
The power unit does not contain any parts that require regular maintenance.
-
Keep the power unit dry and free of dust, dirt and chemicals.
-
Regularly check the earthing of the power unit.
-
Regularly check the connection cables for damage.

10 Faults

Warning:
-
Disconnect the power supply before carrying out work on the unit.
-
Repairs shall be made by a skilled electrical engineer.

10.1 Summary of faults

table 1 faults
Problem
Indicator lamps for switch
and HV indicator stay dark.
HV neon lamp stays dark.
Lamp of switch is lit.
A-Unit_UM_9752080510_NL_D_GB_F_V3_4
Cause
No mains voltage
Power unit is switched off
Faulty switch
Short circuit in connected
equipment.
Transformer is defective
Neon lamp is defective
Remedy
Switch on mains voltage
Switch on power unit
Replace switch
Locate short circuit and
remedy
Replace transformer
Replace neon lamp