USER'S MANUAL FOR TYPE A POWER UNIT

1 Introduction

The power unit serves as a power source for Simco-Ion ionisation equipment. This ionisation
equipment is used to discharge electrostatically charged materials.
The power unit contains a transformer which transforms the mains voltage to the operating
voltage for the ionisation equipment. The neon lamp gives an indication of the high voltage. The
transformer is short-circuit-proof. The maximum output current (short-circuit current) is restricted
in the transformer.
Power cable
Indicator lamp
Indicatielamp
On/off switch
Figure 1: Type A power unit

2 Use and operation

There are four high voltage outputs to which ionisation equipment can be connected. The
indicator lamp indicates whether high voltage is present. In addition to the standard version, the
power unit is available with various options:
-
Remote high-voltage signalling
-
Switch high voltage on/off remotely
-
Output voltage monitoring (at 4 kV)
-
External 12-V power supply