Note: Sometimes the wearing
of tight-fitting undergarments or
a tight pair of jeans will help to
keep the probe in place and maintain
correct contact during the programme.
For Faecal incontinence, the aim is to
stimulate the external sphincter and/or
pubo-rectal
muscle,
electrodes should be placed so that the
external ring is just inside the sphincter.
For Urinary Stress incontinence the aim
is to stimulate the levator muscles and
the probe should be inserted deeper.

16. CLEANING

It is important that the probe is cleaned
before using for the first time and after
each use. Clean with either an alcohol-
free
antibacterial
TensCare Wipes (see X-WIPES) or by
washing with warm soapy water. Rinse
in clean water and dry thoroughly and
return the unit to the storage pouch. Do
not immerse the probe in a liquid.
Clean the case of the unit and lead wire
at least once a week using the same
method.
• Do not immerse your Alivia unit in
water.
• Do not use any other cleaning
solution.

17. EMC

Wireless communications equipment
such
as
wireless
devices,
mobile
telephones and their base stations,
walkie-talkies can affect this equipment
so
circular
wipe
such
as
home
network
phones,
cordless
and should be kept at least a distance d
= 3,3 m away from the equipment.
(Note. As indicated in Table 6 of IEC
60601-1-2:2007 for ME EQUIPMENT,
a typical cell phone with a maximum
output power of 2 W yields d = 3,3 m at
an IMMUNITY LEVEL of 3 V/m).
Note: For hospital use, full
EMC
advice
available on request.
18. DISPOSAL OF WASTE
ELECTRICAL
ELECTRONIC
PRODUCTS (WEEE)
One of the provisions of the European
Directive 2002/96/CE is that anything
electrical or electronic should not be
treated as domestic waste and simply
thrown away. To remind you of this
Directive all affected products are now
being marked with a crossed-out
wheelie bin symbol, as depicted below.
To comply with the Directive, you can
return your old electro-therapy unit to us
for disposal. Simply print a postage-
paid PACKETPOST RETURNS label
from our website www.tenscare.co.uk,
attach this to an envelope or padded
bag with the unit enclosed, and post it
back to us. Upon receipt, we will
process your old device for components
recovery and recycling to help conserve
the world's resources and minimise
adverse effects on the environment.