The union nut (1) permanently attached to the device fits
on all radiator valves of the most common manufacturers
with thread size M30 x 1.5 mm, e.g. Heimeier, MNG,
Junkers, Landis+Gyr (Duodyr), Honeywell-Braukmann,
Oventrop type A, Oventrop AV6, Schlösser, Comap
D805, Valf, Sanayii, Mertik Maxitrol, Watts, Wingenroth
(Wiroflex) R.B.M, Tiemme, Jaga, Siemens, Idmar.
The adapters (14) contained in the supply package en-
able the device to be fitted to Danfoss RA, Danfoss RAV
and Danfoss RAVL radiator valves.
Disassembling the Old Thermostat
Head
1.
Set the thermostat head (12) to its highest setting (11).
This means the thermostat head (12) is no longer press-
ing on the valve pin of the radiator and can be removed
more easily.
2.
Unscrew the fixing element (10) of the thermostat
head (12) using an appropriate tool and remove the
thermostat head.

Installing the New Thermostat Head

To fit the device to Danfoss radiator valves, you need the
adapter (14) provided. To determine which adapter (14)
fits which radiator valve, please refer to Fig. B - D on the
fold-out page.
Caution! Risk of trapping be-
tween the halves of the adapter!
▸ During assembly, be careful not to
jam your fingers between the halves
of the adapter!