Air Quality Sensor
Art.No.: 7009970
INSTRUCTION MANUAL
EN
BEDIENUNGSANLEITUNG
DE
INSTRUCTION MANUAL
EN
About this Instruction Manual
These operating instructions are to be considered a component of the device.
Please read the safety instructions and the operating instructions carefully before use.
Keep these instructions for renewed use at a later date. When the device is sold or given to someone else,
the instruction manual must be provided to the new owner/user of the product.
GENERAL WARNINGS
• Risk of electric shock — This device contains electronic components that operate via a power
source (batteries). Children should only use the device under adult supervision. Only use the device
as described in the manual; otherwise, you run the risk of an electric shock.
• Choking hazard — Children should only use the device under adult supervision. Keep packaging
material, like plastic bags and rubber bands, out of the reach of children, as these materials pose a
choking hazard.
• Risk of chemical burn — Keep batteries out of the reach of children! Make sure you insert the bat-
teries correctly. Leaking battery acid can lead to chemical burns. Avoid contact of battery acid with
skin, eyes and mucous membranes. In the event of contact, rinse the affected region immediately
with a plenty of water and seek medical attention.
• Risk of fire/explosion — Do not expose the device to high temperatures. Use only the recom-
mended batteries. Do not short-circuit the device or batteries, or throw them into a fire. Excessive
heat or improper handling could trigger a short-circuit, a fire, or an explosion.
• Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will
contact the Service Centre and can send the device in to be repaired, if necessary.
• Use only the recommended batteries. Always replace weak or empty batteries with a new, complete
set of batteries at full capacity. Do not use batteries from different brands or with different capaci-
ties. The batteries should be removed from the unit if it has not been used for a long time.
SCOPE OF DELIVERY
Sensor, Operating instructions, 3x AA batteries.
BEFORE YOU BEGIN
• We recommend using alkaline batteries. If temperatures regularly fall below 0°C (32°F), we recom-
mend using lithium batteries.
• Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain correct power
requirements.)
• Insert batteries before first use, matching the polarity in the battery compartment.
3x AA batteries are required.
EC Declaration of Conformity
Hereby, Bresser GmbH declares that the equipment type with part number: 7009970 is in
compliance with Directive: 2014/53/EU. The full text of the EU declaration of conformity is
available at the following internet address:
www.bresser.de/download/7009970/CE/7009970_CE.pdf
UKCA DECLARATION OF CONFORMITY
Bresser UK Ltd. has issued a „Declaration of Conformity" in accordance with applicable
guidelines and corresponding standards. The full text of the UKCA declaration of
conformity is available at the following internet address:
www.bresser.de/download/7009970/UKCA/7009970_UKCA.pdf
Bresser UK Ltd. • Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6HF, Great Britain
NOTES ON CLEANING
• Remove the batteries before cleaning.
• Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do not
use any cleaning fluid.
• Protect the device from dust and moisture.
OVERVIEW
1.
LCD display
2.
[MODE] key
3.
[CHECK] key
4.
Wall mounting holder
BATTERY INSERTION
1.
Unscrew and remove the battery door of
sensor with a screwdriver
2.
Insert the 3 rechargeable batteries (included) into the battery compart-
ment in the following order:
x 3
3.
Screw the battery door compartment on tightly.
4.
After inserting batteries, all LCD segment will be shown for 1 second.
Note:
- Please prepare a screwdriver for removing and close the battery door.
GETTING STARTED
1.
Slide [CHANNEL] to set the channel number
for your sensor(s).
2.
Use a pin to press [RESET] key for run the
channel number.
Note:
- I f there are more than one sensor in use, ensure to assign different channel numbers for
each sensor to enable the measurement to displayed correctly on the console (purchase
of separately).
LCD DISPLAY
1.
PM2.5/PM10 display mode
2.
PM2.5 / PM10 concentration value
3.
PM2.5 / PM10 concentration level
4.
Sensor Wireless channel number
5.
Transmission signal
6.
Battery power indicator
DISPLAY MODE
Press [MODE] to toggle the display mode between PM10 and PM2.5.
[CH1~4] slide switch
5.
6.
[RESET] key
7.
Battery compartment
8.
DC adapter USB power port
3
1
2
1
2
3
4
5
6

Werbung

loading

Inhaltszusammenfassung für Bresser 7009970

  • Seite 1 Transmission signal Battery power indicator Bresser UK Ltd. • Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6HF, Great Britain NOTES ON CLEANING • Remove the batteries before cleaning. • Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do not use any cleaning fluid.
  • Seite 2 MEASUREMENT INTERVAL REPLACE THE RECHARGEABLE BATTERIES Powered by DC adapter Over time, the batteries may degrade in terms of holding the highest capacity for which it The device measures PM2.5 or PM10 concentration every minute automatically when was designed for. If you find the device´s battery power is not lasting as it used to be, it´s powered with a DC adapter. probably a good time to change them.
  • Seite 3: Specifications

    Then visit our website via the link below (QR code) for available versions. Alternatively you can also send an email to manuals@bresser.de or leave a message on +49 (0) 28 72 – 80 74-220*. Please always state your name, precise address, a valid phone number and email address, as well as the article number and name.
  • Seite 4 BATTERIEEINSCHUB Erkennungsintervall Beschreibung (Minute) Schrauben Sie das Batteriefach des Sensors mit einem Schraubendreher auf und ent- 1 (wenn an Adapter angeschlossen) Der Sensor erkennt den PM-Wert jede Minute fernen Sie die Abdeckung 10 (Standard) Der Sensor erkennt den PM-Wert alle 10 Minuten Der Sensor erkennt den PM-Wert alle 20 Minuten Der Sensor erkennt den PM-Wert alle 30 Minuten PM2.5/PM10-KONZENTRATION...
  • Seite 5: Spezifikationen

    Setzen sie den Sensor keiner direkten Sonnenstrahlung aus. (QR Code) für verfügbare Versionen. Alternativ können Sie uns auch eine E-Mail an die Adresse man- uals@bresser.de schicken oder eine Nachricht unter +49 (0) 28 72 – 80 74-220* hinterlassen. Bitte Wandhalterung geben Sie stets Ihren Namen, Ihre genaue Adresse, eine gültige Telefonnummer und E-Mail-Adresse...
  • Seite 6: Service And Warranty

    MANUAL DOWNLOAD: SERVICE AND WARRANTY: www.bresser.de/P7009970 www.bresser.de/warranty_terms Bresser GmbH Gutenbergstr. 2 · DE-46414 Rhede · Germany www.bresser.de · service@bresser.de Bresser UK Ltd. Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6HF, Great Britain...