Herunterladen Inhalt Inhalt Diese Seite drucken

Customer Guidance - Fujitsu ASYG14LECA Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
Filter Sign
The indoor unit has a sign to inform the user that it is time to clean the fi lter. Select the
time setting for the fi lter sign display interval in the table below according to the amount of
dust or debris in the room. If you do not wish the fi lter sign to be displayed, select the set-
ting value for "No indication".
Setting Description
Standard (400 hours)
Long interval (1,000 hours)
Short interval (200 hours)
No indication
Cooling Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a cor-
rection.
The settings may be selected as shown in the table below.
Setting Description
Standard
Slightly lower control
Lower control
Warmer control
Heating Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a cor-
rection.
The settings may be changed as shown in the table below.
Setting Description
Standard
Lower control
Slightly warmer control
Warmer control
Auto Restart
Enable or disable automatic system restart after a power outage.
Setting Description
Yes
No
* Auto restart is an emergency function such as for power failure etc. Do not start and stop
the indoor unit by this function in normal operation. Be sure to operate by the control unit,
or external input device.
Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when using the Wired remote controller temperature
sensor.
Setting Description
No
Yes
* If setting value is "00" :
Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is "01" :
Room temperature is controlled by either indoor unit temperature sensor or remote con-
troller unit sensor.
En-9
All manuals and user guides at all-guides.com
Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
(♦... Factory setting)
Function
Setting Value
Number
00
01
11
External input control
02
"Operation/Stop" mode or "Forced stop" mode can be elected.
03
(♦... Factory setting)
Function
Setting Value
Number
Setting record
Record any changes to the settings in the following table.
00
01
30
Filter sign
02
Cooler room temperature correction
03
Heater room temperature correction
Auto restart
Indoor room temperature sensor switching function
Remote controller signal code
(♦... Factory setting)
External input control
Function
Setting Value
Number
After completing the FUNCTION SETTING, be sure to turn off the power and turn it on
00
again.
01
31
02
03
Explain the following to the customer in accordance with the operating manual:
(1) Starting and stopping method, operation switching, temperature adjustment, timer, air
(2) Air fi lter removal and cleaning, and how to use the air louvers.
(3) Give the operating manual to the customer.
(♦... Factory setting)
Function
Setting Value
Number
00
40
01
(♦... Factory setting)
Function
Setting Value
Number
00
42
01
Setting Description
A
B
C
D
Setting Description
Operation/Stop mode
(Setting forbidden)
Forced stop mode
Setting Description

14. CUSTOMER GUIDANCE

fl ow switching, and other remote control unit operations.
(♦... Factory setting)
Function
Setting Value
Number
00
01
44
02
03
(♦... Factory setting)
Function
Setting Value
Number
00
46
01
02
Setting Value

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis