Herunterladen Inhalt Inhalt Diese Seite drucken

Sensica SENSILIGHT mini Bedienungsanleitung Seite 14

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
recommended for small areas
such as face, bikini line and
underarm.
For gliding mode
or continuous flashes, keep
the trigger button pressed
and start moving the device
with each flash to the next
spot without detaching it
Status
Status
Indicator
No light
OFF
Steady
ON
green light
Blinking
Standby
green light
Momentary
Flash
blocked
orange light
Blinking
Close to
end of life
orange light
Momentary
Flash
red light
blocked
14
from the skin. The device will
immediately recharge and
will be ready for the next
flash. Repeat process until
the entire treatment area has
been covered. This method is
recommended for larger areas
such as legs.
Description
Device not working (not
connected to the power supply).
Flash is ready to be delivered.
Device is in standby mode
(before powering on or when left
unattended for 3 minutes).
The device is not in full contact
with the skin – no flash will be
delivered.
Indicates about the close end of
lamp life time.
The skin in the treated area is too
dark – no flash will be delivered.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ipl030

Inhaltsverzeichnis