Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Maintenance - IFM Electronic efector200 OC Serie Bedienungsanleitung

Reflexlichtschranke
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Select one of the following modes by applying a High signal (+10 V...U
to the ET connection:
Mode I (e.g. PET bottles, transparent films)
Duration of the High signal to the control wire between 30-100 ms.
Recommended signal duration: 50 ms
3
Mode II (e.g. clear glass bottles)
Duration of the High signal to the control wire between 100-200 ms.
Recommended signal duration: 150 ms
Mode III (e.g. coloured glass bottles)
Duration of the High signal to the control wire > 200 ms
Recommended signal duration: 250 ms
Approx. 2 s after applying the HIGH signal, the function display will be
4
The mode remains set even if supply voltage is switched off (non-volatile
To select another mode follow points 1 to 4 once again.

Operation

Check the safe functioning of the unit.
The function LED is lit when light is received (= no object between unit
and reflector)
• PNP version
Output: light-on mode, when the light beam is interrupted the output
is LOW.
FC: function-check output [safe detection: approx. 0 V; incorrect
Teach-In or severe soiling: U
• NPN version
Output: light-on mode, when the light beam is interrupted the output
is HIGH.
FC: function-check output (safe detection: approx. U
In or severe soiling: approx. <1.8 V)

Maintenance

Keep the lens of the sensor free from soiling. For cleaning do not use
any solvents or cleaning agents which could damage the plastic lenses.
All manuals and user guides at all-guides.com
constantly lit. Setting has been completed.
- (<2.9 V)].
B
memory).
; incorrect Teach-
B
)
b
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis