Setting the operating range
• manually via the Mode switch
1
2
Set the Mode switch to Teach, after 2 s
the function display flashes and the
3
operating mode of the sensor can be
Select one of the following modes by
setting the Mode switch as follows:
Mode I
(e.g. PET bottles, transparent films)
4
Mode II
(e.g. clear glass bottles)
Mode III
(e.g. coloured glass bottles)
Approx. 2 s after selecting the Mode, the function display will be con-
5
The mode remains set even if supply voltage is switched off (non-volatile
To select another mode follow points 1 to 5 once again.
• externally via ET control wire
1
Set the Mode switch to EXT, after 2 s
the function display flashes and the
2
operating mode of the sensor can be
6
All manuals and user guides at all-guides.com
Do not connect the ET (or 0 V) connection.
Ensure that no object is in the light beam.
set.
stantly lit. Setting has been completed.
Ensure that no object is in the light beam.
set.
memory).