Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser liquipoint T FTW 31 Bedienungsanleitung Seite 35

Füllstandgrenzschalter mit integriertem elektronikeinsatz
Vorschau ausblenden Andere Handbücher für liquipoint T FTW 31:
Inhaltsverzeichnis

Werbung

Fault
Reason
Does not switch
No power
Faulty signal line
Faulty electronic insert
Strong build-up
FEW 54: contacts welded
together (after short-circuit)
Conductivity of liquid too low
Switches
Min-/Max- fail-safe mode set
incorrectly
wrongly
Faulty switching
Thick heavy foam,
sporadic
very turbulent conditions,
foaming liquid
Extreme radio interference
Water in housing
FEW 52: output overloaded
Endress+Hauser
Remedy
Check power
Check signal line
Exchange
Select suitable measuring
range setting (see Page 26-28)
Exchange FEW 54;
put fuse in contact circuit
Select different measuring
principle
Set correct mode at electronic
insert
Mount device in a bypass
if necessary
Screen connecting cable
Clean cover and cable gland
and screw tight
Reduce load,
(cable) capacitance
Trouble-shooting