P135 / P135K
TECHNICAL DATA
Range:
0...100 mbar to 0...20 bar
Output:
4 ...20 mA 2-wire
Accuracy:
≤ ± 0,25% FS @ 25°C
Power supply:
12...30V
Ambient temp.:
-20...70 °C Ex ia IIC T4 Ga
medium temp.:
-20...70 °C Ex ia IIC T4 Ga
storage temp.:
-40...85 °C
Temperature coeff.: ≤ ± 0,02% FS/K
Long term stability: ≤ ± 0,2% FS p. a.
Housing:
stainless steel 1.4404
Protection class:
IP 68
weigth of sensor:
approx. 0,3 kg
weigth of cable:
0,5 kg / 10m
Sensor:
Ceramic AL
Nöding Messtechnik GmbH • Oldenfelder Bogen 29 • D-22143 Hamburg, Germany • Tel.: +49 40 67 58 51 – 0
Fax: +49 40 67 58 51 – 49 • Internet: www.noeding-messtechnik.de • E-mail: info@noeding-messtechnik.de
Operating instructions level transmitter
0
2
3
P135 / P135K
ORDERING CODE
Output signal
4...20 mA 2-wire
4
4...20 mA 2-wire and PT100 3-wire
T
4...20 mA 2-wire and PT1000 3-wire
F
EX 4...20 mA 2-wire, II 1G Ex ia IIC T4 Ga
TX 4...20 mA 2-wire, II 1G Ex ia IIC T4 Ga und PT100 3-wire
FX 4...20 mA 2-wire, II 1G Ex ia IIC T4 Ga und PT1000 3-wire
Range
See table „Ranges"
99 non standard range
Material Housing / Sensor seal
1.4404 / FPM (Viton)
1
1.4404 / EPDM
2
1.4404 / FPM (Viton) und Serto
S
EN
cable lenght
2m cable
002
5m cable
005
10m cable
010
50m cable
050
100m cable
100
special lenghts quote in meters
Material cable
0 PE cable
2 PUR cable
4 HDPE
6 FEP cable
Options
lightning
B
protection