Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms!
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Connections:
Thermal disinfection:
The product is exclusively designed for drinking water!
Safety against backflow
Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heaters
if the flow pressure is at least 0,15 MPa.
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work
4
English
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
cold right - hot left
max. 70°C / 4 min
Cause
- Shower filter seal dirty
- check valve hasn't moved back
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Flow limiter in handshower isn't
removed
- Filters are dirty
- check valve hasn't moved back
Assembly see page 12
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 15)
To adjust the hot water limiter on single lever
mixers, please see page 15. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Operation (see page 16)
Maintenance (see page 17)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Dimensions (see page 18)

Flow diagram

(see page 18)
Spare parts (see page 20)
Test certificate (see page 24)
Cleaning
see enclosed brochure.
Remedy
- Clean filter seal between shower
and hose
- Exchange check valves
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange check valves