Basic Settings; Configuration Of The Inputs - IFM Electronic ecomot200 DY 340 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Parameter
start-up delay for OUT 1 (min.)
The output switches after the start-up delay
P29
has elapsed.
The time starts with the application of the
operating voltage or after reset.
mean-value generation
display value = measured value of the
P30
current measuring cycle or mean value of a
number of preceding measuring cycles
1 measuring cycle = 200ms
reset time
reset of the display when the current value
P31
falls below a minimum input frequency or
a maximum time interval between 2 input
pulses is exceeded
P74 delete min./max. memory
Settings for analog outputs (only for the article E89121)
final analog value
display value at which the analog output
P33
supplies the maximum output signal
P34 type of the analog signal
adaptation of the analog zero value
P35
display value at which the analog output
supplies the minimum output signal ("0")
P36 maximum output level of the analog output

7. Basic settings

7. 1. Input configuration
These two parameters must always be set:
1. Set the unit to the level of the pulse pick-ups with the parameter P03
(P03 = 1: HTL / P03 = 2: TTL).
2. Set the unit to the electrical design of the pulse pick-ups with the parameter P04
(P04 = 1: npn switching / P04 = 2: pnp switching).
These two settings apply to all 4 inputs.
Configuration with the connection of NAMUR pulse pick-ups: P03 = 1 and P04 = 1.
The level of the input signal depends on the setting with P04:
- signal = HIGH if P04 = 2 (pnp switching),
- signal = LOW if P04 = 1 (npn switching).
The following parameters can be set as needed:
• Frequency division: reduction of the input frequency in 5 defined division ratios
(parameter P05 for input A, parameter P06 for input B).
• Function assignment for the inputs C and D: A signal to the input executes one of
the following functions: reset, counting interruption, reset min/max, keyboard
locking (parameter 21 for input C, parameter P22 for input D).
Parameter value
range of values:
0s = start-up delay not active
0.01 ... 99.98s start-up delay active
99.99s = output "min." remains locked until the
current value falls below the preset min. value
for the first time
1 = no mean-value generation
display value = value of the current
measuring cycle
2 ... 16 = mean-value generation across the last
2 ... 16 measuring cycles
0 ... 99.99s
0 = do not delete memory
1 = delete memory
range of values: 0 ... 999 999
1 = 0 ... ±10 V (max. 5 mA)
2 = 0 ... 20 mA (max. load: 300 Ω)
3 = 4 ... 20 mA (max. load: 300 Ω)
range of values: -2000 ... +2000
1000 = 10.0 V / 20.0 mA
600 = 6.0 V / 12.0 mA
150 = 1.5 V / 3.0 mA