Herunterladen Inhalt Inhalt Diese Seite drucken

Adjustable Parameters - IFM Electronic ecomot200 DY 340 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6. Adjustable parameters

Parameter
P00 keyboard locking
P01 operating mode
P02 operand:
numerical value to calculate the display value
P03 input level for all inputs
P04 input characteristics for all inputs
P05 frequency division for input A
P06 frequency division for input B
P07 decimal point of the display
P08 start/stop characteristics for time measurement 1 ... 5 (see page 28)
P09 reset characteristics for time measurement
preset 1 (minimum value):
P10
display value at which OUT 1 (min.)
is to switch
preset 2 (maximum value):
P11
display value at which OUT 1 (max.)
is to switch
switching characteristics of the outputs
P12
OUT 1 (min.) and OUT 2 (max.)
P15
last value memory for time measurement
fleeting time for OUT 1 (min.)
The output changes its switching status
when the current value is above or below
P18
the limit value for the length of the set
fleeting time.
Then it returns to the initial status.
P19 fleeting time for OUT 2 (max.)
P20 fleeting time for OUT 3 (display 0)
P21 function assignment for input C
P22 function assignment for input D
P23 function assignment for the
P24 function assignment for the
P25 function assignment for the
P26 read min. value memory
P27 read max. value memory
direction-dependent display /
P28
direction signal by OUT 3
page 20
Parameter value
0 = keyboard locking inactive
1 = keyboard locking active
1 ... 23 (see from page 23)
range of values: 1 ... 50 000
(see from page 23)
1 = HTL (LOW= 0 ... 5 V HIGH = 8 ... 30 V)
2 = TTL (LOW= 0 ... 1 V HIGH = 2.5 ... 6 V)
1 = NPN
2 = PNP
1 = 1:1
2 = 1:10
3 = 1:100
4 = 1:1000
5 = 1:10 000
range of values: 0 ... 5
0 = none, 5 = 5 decimal places
1 ... 4 (see page 29)
range of values: 0 ... 999 999
range of values: 0 ... 999 999
1 = both outputs switch when the relevant preset
value has been exceeded
2 = output (min.) switches when the current value
is below the preset value, output (max.) switches
when the curent value is above the relevant preset
value
1 = ON / 2 = OFF
range of values: 0.00 ... 9.99s
(0.00 = fleeting time not active, output is switched
statically)
0 = no function
5 = delete min./max. memory
6 = keyboard locking
7 = counting interruption
8 = reset
0 = no function
button
5 = delete min./max. memory
button
7 = counting interruption
8 = reset
button
display of the current minimum value
display of the current maximum value
1 = without sign, without direction signal
2 = with sign and direction signal OUT 3
(see page 23)

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis