3. Mounting

Mount the unit with two clamps in the control panel, cutout 91 x 43mm.

4. Electrical connection

Disconnect the installation before connecting the unit. The plug-in terminal
strip features reverse polarityprotection.
Connection:
X1
GND
1
+24 V DC IN
2
GND
3
+5 V DC OUT
4
5
+ 12 V DC OUT
6
Input A
7
Input B
8
Input C
9
Input D
10
GND
10 V
11
+ / -
12
+
20 mA
13
-
14
OUT 1 (min)
15
OUT 2 (max)
16
OUT 3 (display 0)
17
+ 24 V Com
X2
L 230 V AC
L 115 V AC
N
page 18
DC supply
sensor supply
signal inputs
analog outputs
(Only for the article
E89121,
with all other units
these terminals must
not be used).
outputs
AC supply
Voltage supply
• either AC on terminals L/N
• or DC on terminals 1 and 2.
Sensor supply
• either internally by DY340 (5V on
terminals 3 and 4, 12 V on terminals
3 and 5)
• or externally.
With an external sensor supply, L- of
the external source must be connected
with terminal 3 of the DY340.
In the case of DC operation of the
DY340 the sensor can be directly sup-
plied by the supply voltage (external).
The terminals 1 to 17 are electrically
isolated from the mains.