Herunterladen Inhalt Inhalt Diese Seite drucken

Inflating The Board - Mistral HG06954 Montage-, Bedienungs- Und Sicherheitshinweise

Aufblasbares stand-uppaddle-board
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 69
Remove all product packaging.
Verify that all parts are present and in good
condition.
When unrolling the board
no sharp objects such as shards of glass, loose
gravel or glowing charcoal or cigarette butts
are on the ground.
Note: Check the board for any damage such
as holes and tears the second time it is assem-
bled or sooner. Please refer to chapter "Repair
and maintenance" how to repair these. Damage
cannot be repaired once you are on the water.
Unroll the board
and remove the plastic
1
foam fin protector
from the two fins.
15
Note: Do not throw away the fin protector
These are required to protect the fixed fins when
rolling up the board
1

Inflating the board

Avoid overinflating to prevent the welded
seams from over-expanding or even rupturing.
Only inflate up to a pressure of 1 bar (15 PSI).
The air pressure will increase when the product
heats up from the sun. In this case, reduce the air
pressure by releasing air from the board
Inflate the board
with the included air pump
1
. You can alternatively use a standard foot
13
pump or twin stroke piston pump with the cor-
responding attachments and a pressure gauge.
Only open the valves
release air. They can otherwise become
dirty.
The area around the valve
be dry and clean. Check the valve
particles.
Ensure sand or other dirt does not enter the
valve
.
1a
You may also use electric pumps designed spe-
cifically for SUP boards. These pumps are pre-
set to 15 PSI; the pump automatically shuts off
when this air pressure is reached.
Screw the threaded coupler
onto the male thread
13a
the air pump
. Be sure to screw the hose
13
onto the thread marked "INF" (Fig. B).
, ensure there are
1
.
15
after use.
.
1
to inflate or
1a
must always
1a
for dirt
1a
of the hose
14a
14
of the connector on
14
Set the air pump
13
the front lever to the right (Fig. F1). Now inflate
the board
.
1
Once you notice a lot of force is required, set
the air pump
to single stroke by moving the
13
front lever to a vertical position. You can now
continue inflating with considerably less force.
Note: Do not pull the handle on the air pump
all the way up, only far enough so your arms
13
remain straight (Fig. F2). Now use the weight
of your body to inflate the product by simply
bending at the knees. Keep your arms straight.
This way you are not inflating with your arm
muscles but the weight of your body (Fig. F3).
Inflate the board
1
the recommended pressure of 1 bar (15 PSI).
Use the pressure gauge to check the pressure.
Stop inflating the product once the pressure
gauge reads 1 Bar (15 PSI).
Inflate in the following order:
1. First inflate the air chamber with valve number
1. The valves are marked 1 and 2.
2. Turn the valve head clockwise so it comes out
upward (Fig. C1).
3. Then open valve 2 and turn the valve head an-
ti-clockwise whilst pushing down (Fig. C4).
Your board
is now ready to inflate.
1
4. Start with valve 1 by inserting the hose
the valve
and securing it all the way clock-
1a
wise (Fig. C2).
Note: The valve head must be in the closed
position.
5. Then inflate the second air chamber via valve
2. To do so, turn the valve head clockwise so
it comes out upward (Fig. C1), insert the pump
hose the same as with valve 1 and start inflat-
ing. Since the inner air chamber is small, leave
the front lever on the air pump
inflate using little force.
6. Unscrew the hose end anti-clockwise from the
valve
and attach the valve cap
1a
valve
.
1a
7. Tighten the valve cap
to twin stroke by moving
with the air pump
to
13
into
14
vertical to
13
to the
1e
, turning clockwise.
1e
GB
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Mistral HG06954

Inhaltsverzeichnis