Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Cleaning The Device - Bosch MSGP3L Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für MSGP3L:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en Cleaning the device
There are 2 ways to descale the device:
Using citric acid
Prepare the descaling solution.
1.
Add 2 teaspoons of citric acid to
warm water at 50 °C.
Slowly pour the descaling solution into
2.
the plant tray.
Maximum capacity has been reached
when the light unit flashes white twice.
Using descaling tablets
Place 1 descaling tablet in the water
1.
bowl with lukewarm water.
Wait approx. 5 minutes until the tablet
2.
has dissolved.
Ordering descaling tablets
Order descaling tablets from customer ser-
vice.
Quantity
6 x 18 g
12 x 18 g

Troubleshooting

Troubleshooting
You can rectify minor faults on your appliance yourself. Read the troubleshooting informa-
Troubleshooting
tion before contacting after-sales service. This will avoid unnecessary costs.
Fault
Light unit will light up
continuously red until the
water bowl is removed.
Light unit does not light
up.
18
Order number
311864
311893
Cause and troubleshooting
The pump is blocked or the impeller is missing.
Check that the pump impeller is positioned correctly.
1.
Check that the pump housing is positioned correctly.
2.
The device is standing on a magnetic metal surface.
Check whether the location is suitable in the long term.
1.
General information
Select a different location.
2.
Device is not connected to the power supply.
Check whether the power supply is plugged into a
1.
socket.
Check whether the connecting cable is properly connec-
2.
ted to the docking unit.
Starting the descaling process
→ Fig.
25
a The pump will run for around 3 minutes.
Notes
¡ If not all deposits have dissolved, leave
the descaling solution to work for at least
2 hours and then start the pump again.
¡ If necessary, leave the descaling solution
to work in the bowl overnight.
device
the
Cleaning

Cleaning the device

device
the
Cleaning
Note: After descaling, clean all parts thor-
oughly.
→ Fig.
 - 
26
30
Notes
¡ Clean all parts as indicated in the clean-
ing overview.
¡ After drying re-assemble all parts in re-
verse order.
¡ When inserting the pump impeller, check
that there are no residues on or under-
neath the impeller. The pump impeller
must turn easily.
cleaning
of
Overview
Overview of cleaning
cleaning
of
Overview
→ Fig.
31
Printed on 100% recycled paper

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis