Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Area; Aligning The Appliance - Schulthess proLine D200 Aufstellanleitung

Professioneller wäschetrockner
Vorschau ausblenden Andere Handbücher für proLine D200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Re-insert cover and drawer
Tighten the screws on the cover after transportation .
Re-insert the filter drawer .

Installation area

Maximum floor load (without socle) in operating
status:
D 200
2 125 N
In order to ensure the stability of the appliance during
spin drying, the installation area must be firm and
level .
Soft floor coverings, e .g . fitted carpets or coverings
with a foamed material backing are not suitable as an
installation area .
Keep the area surrounding the dryer free of dust and
fluff .
D 325
2 650 N
Keep machine dimensions in mind
Notice
The machine can be placed with its back against a
wall . The minimum distance between the machine and
the wall or possibly another machine is 50 cm .
135 cm
Take note of the appliance measurements and the
space required to connect it to an exhaust air duct .

Aligning the appliance

Notice
The machine must be in a vertical position with all
four feet firmly on the floor and it must not wobble .
Do not remove the screw feet under any circumstances .
Align the appliance with the help of a spirit level on all
sides .
79 cm
90 cm (D 200)
120 cm (D 325)
> 50 cm
EN
37

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Proline d325

Inhaltsverzeichnis