DANGER
Danger to life due to electric shock
Touching electrically live parts can be fatal.
a) Switch off the device and pull out the mains
plug.
20.1

Decommissioning

a) Switch off the device and disinfect it (see Check-
ing and cleaning the device
b) Disconnect the power plug.
 The device has been decommissioned.
20.2

Storing the device

a) Store the device free of frost and in a dry loca-
tion.
Attention
Damage caused by improper storage
If the temperature at the storage place drops below
0 °C, the device might be damaged by frost.
a) Only place the device in storage once it has
been drained and disinfected within the speci-
fied temperature range (see Technical details
[
31]).
20.3

Disposal

The device is primarily made of recyclable materials.
It does not represent any danger to the operator and
the environment when handled properly.. However,
operation of the device may lead to the generation of
waste and waste water containing harmful and/or
environmentally hazardous substances (air filters
and condensate). These materials must be disposed
of safely in accordance with the regulations.
The individual components of the device (e.g.
pumps, metal components, etc.) must be taken to a
qualified disposal and recycling company. Commis-
sion a qualified, specialist company to dispose of
and recycle the device.
See also
 Contact to HEYLO GmbH
EN
[
29]).
[
20]
21

Technical details

Model
ACV100 ACV200 ACV400
Product number
2202702 2202701 2202700
Air throughput [m³/h]
12000
Cooling filter size
120
[dm²]
Electric power con-
450
sumption [W]
Current consumption
2,7
[A]
Electrical connection
220-240
[V/Hz]
/ 50
Fuse protection [A]
10
Protection class [IP]
44
Water consumption
8-10
[l/h]
Max. noise emission
67
[dB(A) / 3m]
Room size [m²]
150
Water tank capacity [l] 80
Operating temperature
5-35
[°C]
Storage temperature
1-35
[°C]
Length x width x
925 x
height [m]
580 x
1430
Weight [kg]
45
Surge tank [inch /
1/2" / 3
max. pressure in bar]
Air cooler ACV 100 / 200 / 400
22000
30000
180
340
750
1300
4,5
6,8
220-240
220-240
/ 50
/ 50
10
10
44
44
10-15
15-20
68
70
250
400
120
200
5-35
5-36
1-35
1-36
1130 x
1690 x
690x164
920 x
0
1910
59
105
1/2" / 3
1/2" / 3
31 / 33