Caution:
The "main switch" should be used for for
emergency functions only (e.g., battery
overheating protection etc.), since the
status data are only stored while drawing
the power plug with the main switch on.
The current data are lost while switching
off via "main switch"! It can in particular
happen that the charger after a disconnec-
tion with the "main switch" can not be
switched on again since the data of the last
full charging are still stored; as a result,
the charger remains in the state "charging
ended".
Reset by:
• Disconnect mains
• "Main switch" on
• Connect Pin 10 and 18, as well as Pin
9 and 12. (See also schematic dia-
gramm 7.8)
• Reconnect to mains
externe Hilfsversorgung
Auxiliary power
+12 V
Pin 18
Abb a)
NLG4 C
NLG-4
Pin 12 (+12V)
Pin 11
Ground
Achtung:
Der "Hauptschalter" sollte nur für Notfunk-
tionen (z.B. Thermostat etc.) verwendet
werden, da die Zustandsdaten nur beim
Ziehen des Netzsteckers mit eingeschalte-
tem Hauptschalter abgespeichert werden.
Beim Ausschalten via Hauptschalter gehen
die aktuellen Daten verloren! Insbesondere
kann es passieren, dass sich das Ladegerät
nach einem Unterbruch mit dem Haupt-
schalter nicht mehr einschalten lässt, da es
die Daten der letzten Volladung noch ge-
speichert hat; dadurch bleibt das Gerät im
Zustand "Ladung beendet"
Reset durch:
• Netzstecker ausstecken
• Hauptschalter einschalten
• Zündung kurzzeitig aktivieren oder mit
Pin 12 (HVS) verbinden. (Pin 10 mit
18, sowie Pin 9 mit 12 verbinden, siehe
auch Schema unter 7.8)
• Netzstecker einstecken
externer Schaltkontakt
external switched contact
Pin 12 (+12V)
Pin 11
Pin 18
Abb b)
NLG-4
Ground
18