Herunterladen Inhalt Inhalt Diese Seite drucken

Electricity Supply; Switching Off; Care And Maintenance - Comet Spa KSX 1850 GOLD Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 41
system as possible.
Failure to comply with the above conditions
causes serious mechanical damage to the pump
and the loss of warranty cover.
Water supply from the potable water mains
· Connect a supply hose (not included)
to the water inlet of the unit and to the
water supply.
· Open the tap.
Water supply from an open container
· Unscrew the coupling part for the water
inlet.
· Screw the suction hose with filter (not
included) onto the water connection of
the unit.
· Hang the filter in the container.
· Vent the unit before operation.
· Unscrew the high-pressure line at the
high pressure outlet of the unit.
· Switch on the unit and let it run until
water free of bubbles emerges at the
high-pressure outlet.
· Switch off the unit and screw on the
highpressure hose again.
> ELECTRICITY SUPPLY
- The electrical connection of the appli-
ance must be carried out by a QUALIFIED
ELECTRICIST and conform to the norm
IEC 60364-1.
WARNING: Before connecting the
appliance, make sure that the nameplate
data are the same as those of the electri-
cal mains and that the socket is protect-
ed by a differential security breaker with
tripping sensitivity below
0.03 A - 30 ms.
- If the appliance's plug is not compatible
with the socket, have the socket re-
placed with another of suitable type by
professionally qualified staff.
- Never use the appliance in ambient
temperatures below 0° C if it is equipped
with a PVC
(H VV-F) cable.
WARNING: Inadequate extension
cords can be dangerous. If an exten-
sion cord is used, it must be suitable for
outdoor use connections must be dry,
away from the ground and a cable reel
must be used so that the socket is at
a distance of at least 60 mm from the
ground.
<16 A
<20 m
ø 1,5 mm
14 AWG
20 m - 50 m ø 2,5 mm
12 AWG
IMPORTANT: The Total Stop device,
which stops the machine during the
bypass phase. To start the water cleaner,
it is therefore necessary to set the switch
on position (I)"ON"; after that press the
pistol trigger. The Total Stop System will
start the machine and will stop it auto-
matically when the trigger is released. It
is advisable to put on the safety of the
pistol trigger whenever the machine is
stopped, in order to avoid unintentional
starting.
· Any automatic start of the ma-
chine without pressing the gun
trigger is attributable to air bub-
bles in the water or other similar
phenomena which do not imply
the existence of any defects in
the machine.
· Do not leave the appliance unat-
tended during the standby for
more than 5 minutes. Contrarily,
for the safety of the appliance it
is necessary to re-turn the switch
into the (0) OFF position.
· Please check that the coupling of
the high pressure hose with the
appliance and the gun supplied
as standard equipment made
correctly, that is to say without
any water leak.

SWITCHING OFF

See fig. C

CARE AND MAINTENANCE

EN
<25 A
ø 2,5 mm
2
2
12 AWG
ø 4,0 mm
2
2
10 AWG
23

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis