NOTE: Depending on the conditions of use and the
ambient temperature, the indication may differ slightly
from the actual capacity.
NOTE: The first (far left) indicator lamp will blink when
the battery protection system works.
Tool / battery protection system
The tool is equipped with a tool/battery protection sys-
tem. This system automatically cuts off power to the
motor to extend tool and battery life. The tool will auto-
matically stop during operation if the tool or battery is
placed under one of the following conditions:

Overload protection

When the tool or battery is operated in a manner that
causes it to draw an abnormally high current, the tool
automatically stops without any indication. In this sit-
uation, turn the tool off and stop the application that
caused the tool to become overloaded. Then turn the
tool on to restart.

Overheat protection

When the tool or battery is overheated, the tool stops
automatically and the lamp blinks. In this case, let the
tool and battery cool before turning the tool on again.
Overdischarge protection
When the battery capacity is not enough, the tool stops
automatically. In this case, remove the battery from the
tool and charge the battery.
Switch action
WARNING:
Before installing the battery car-
tridge into the tool, always check to see that the
switch trigger actuates properly and returns to
the "OFF" position when released.
CAUTION:
When not operating the tool,
depress the trigger-lock button from
lock the switch trigger in the OFF position.
► Fig.3: 1. Switch trigger 2. Trigger-lock button
To prevent the switch trigger from accidentally pulled,
the trigger-lock button is provided. To start the tool,
depress the trigger-lock button from A side and pull the
switch trigger. Release the switch trigger to stop. After
use, press in the trigger-lock button from B side.
Speed change
The revolutions and blows per minute can be adjusted
by turning the adjusting dial. The dial is marked 1 (low-
est speed) to 5 (full speed).
► Fig.4: 1. Adjusting dial
Refer to the table below for the relationship between the
number on the adjusting dial and the revolutions and
blows per minute.
Number
CAUTION:
the tool is running. Failure to do so may result in
the loss of control of the tool and cause an injury.
NOTICE:
low speed for a long time, the motor will get over-
loaded, resulting in tool malfunction.
NOTICE:
only as far as 5 and back to 1. Do not force it past
5 or 1, or the speed adjusting function may no
longer work.
NOTE: Soft no-load rotation function
When the speed adjusting dial is set to "3" or higher,
the tool automatically reduces the speed at no-load to
reduce the vibration under no-load.
Once operation starts with a bit against concrete,
blows per minute increase and reach the numbers as
shown in the table.
When temperature is low, the tool may not have this
function even with the motor rotating.
Lighting up the front lamp
► Fig.5: 1. Lamp
CAUTION:
source of light directly.
Pull the switch trigger to light up the lamp. The lamp
side to
keeps on lighting while the switch trigger is being pulled.
The lamp goes out approximately 10 seconds after
releasing the switch trigger.
NOTICE:
few seconds, the active feedback sensing tech-
nology is not working properly. Ask your local
Makita Service Center for repair.
NOTE: Use a dry cloth to wipe the dirt off the lens of
the lamp. Be careful not to scratch the lens of lamp, or
it may lower the illumination.
Selecting the action mode
NOTICE:
knob when the tool is running. The tool will be damaged.
NOTICE:
change mechanism, be sure that the action mode
changing knob is always positively located in one
of the three action mode positions.
13 ENGLISH
Revolutions per
minute
5
500
4
470
3
380
2
290
1
250
Do not turn the adjusting dial when
If the tool is operated continuously at
The speed adjusting dial can be turned
Do not look in the light or see the
If the lamp goes off after blinking for a
Do not rotate the action mode changing
To avoid rapid wear on the mode
Blows per minute
2900
2700
2150
1650
1450