Herunterladen Inhalt Inhalt Diese Seite drucken

S+S REGELTECHNIK AERASGARD RFTM-LQ-PS-CO2-Modbus Bedienungs- Und Montageanleitung Seite 15

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 3
G
AERASGARD
®
Schematic diagram
1 2 3 4
shield
ON
1 2 3 4 5 6
shield
1 2 3 4
Sensor
Plug for
VOC
display
Sensor
CO
2
ON
DIP A
1 2 3 4 5 6 7 8
address
VOC
VOC
°C
r.H.
CO ² CO ²
offset
zero
AERASGARD
®
Rxx - Modbus
Type ⁄ WG02
RCO2 - Modbus
RCO2-Modbus
RCO2-Modbus LCD
RLQ - CO2 - Modbus
RLQ-CO2-Modbus
RLQ-CO2-Modbus LCD
RFTM - PS - Modbus
RFTM-PS-Modbus
RFTM-PS-Modbus LCD
RFTM - CO2 - Modbus
RFTM-CO2-Modbus
RFTM-CO2-Modbus LCD
RFTM - CO2 - Modbus - P
RFTM-CO2-Modbus-P
RFTM-CO2-Modbus-P LCD
RFTM - LQ - CO2 - Modbus
RFTM-LQ-CO2-Modbus
RFTM-LQ-CO2-Modbus LCD
RFTM - LQ - PS - CO2 - Modbus
RFTM-LQ-PS-CO2-Modbus
RFTM-LQ-PS-CO2-Modbus LCD
Note:
RFTM - LQ - PS - CO2 - Modbus
R xx - Modbus
Sensor
Plug for
VOC
display
Sensor
CO
2
DIP B
ON
DIP A
1 2 3 4 5 6 7 8
mode
address
°C
r.H.
VOC
CO ² CO ²
offset
zero
DIP A: Bus address
DIP B: Bus parameters
(Baud rate, parity ...)
Telegram indicator
1 2 3 4
Reception (LED green)
Error (LED red)
Shielding
Offset correction
LED (internal status)
Button
1 2 3 4
Room sensor and measuring transducer for
humidity, temperature, air quality (VOC), fine dust (PM) and CO2 content, Deluxe
Measuring Range
Humidity
Temperature
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
These units must not be used as safety-relevant devices!
Schematic diagram
(with Potentiometer)
DIP A: Bus address
DIP B: Bus parameters
(Baud rate, parity ...)
Telegram indicator
1 2 3 4
Reception (LED green)
Error (LED red)
Shielding
Offset correction
LED (internal status)
Button
1 2 3 4
VOC
Plug for
display
Sensor
CO
shield
2
ON
DIP B
ON
DIP A
1 2 3 4 5 6
1 2 3 4 5 6 7 8
mode
address
shield
CO ²
zero
PM
CO2
5000 ppm
5000 ppm
5000 ppm
5000 ppm
0...1000 µg/m
3
0...1000 µg/m
3
5000 ppm
5000 ppm
5000 ppm
5000 ppm
5000 ppm
5000 ppm
0...1000 µg/m
3
5000 ppm
0...1000 µg/m
5000 ppm
3
15
RFTM - CO2 - Modbus - P
Plug for
display
Sensor
CO
shield
2
ON
DIP B
ON
1 2 3 4 5 6
1 2 3 4 5 6 7 8
mode
address
shield
CO ²
zero
DIP A: Bus address
DIP B: Bus parameters
(Baud rate, parity ...)
Telegram indicator
Reception (LED green)
Error (LED red)
Shielding
Button
LED (internal status)
Potentio-
meter
Display
Item No.
VOC
P
=
1501-61B0-6001-200
1501-61B0-6021-200
0...100 %
1501-61B1-6001-500
0...100 %
1501-61B1-6021-500
1501- 2116-6001- 200
1501-2116 -6021- 200
1501-61B6-6001-200
1501-61B6-6021-200
1501-61B6-6501-271
1501-61B6-6521-271
0...100 %
1501-61B8-6001-500
0...100 %
1501-61B8-6021-500
0...100 %
1501- 2119-6001- 500
0...100 %
1501-2119 -6021- 500
Rev. 2021 - V30
D
D
(B
Te
R
E
Sh
B
DIP A
L
Potentio-
meter

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Aerasgard rftm-lq-co2

Inhaltsverzeichnis