LCD PROPERTIES

The display not only shows the operating
status of the PoE port, but also the state of
each port, such as e.g.:
Output power
Overload
Short circuit
Low workload
1.
Shows the individual ports. The fi rst 10 ports are displayed on the fi rst page, the rest
on the next page.
2.
Shows the status or the provided power of each port, in this case port 2 provides
8.4W for the PoE device
3.
Shows the download bandwidth in real time
4.
Shows the upload bandwidth in real time
Short
Meaning
Overload protection. An overload was detected on the powered device
OLP:
ULP:
Underload protection. An underload was detected on the powered device
Short-circuit protection was activated for the port of the powered device
SCP:
OFF:
The corresponding port is inactive
----W:
Indicates that no powered device to be supplied with power is connected to this port
---M:
Indicates that there is no data transmission on this port
<1M:
Indicates that on this port the data transfer rate is less than 1Mbps
856M:
If the data transfer rate (here 856Mbps as an example) is displayed in white or green, it
is within the range of the preset bandwidth warning or no bandwidth warning has been
activated. If it is displayed in red, the bandwidth is higher than preset.
The different colors of the respective lines (green and white) serve the clari-
ty. If a port is displayed in green or white with „OFF", it is inactive. Selective
activation/deactivation can be carried out via the menu item „07:PSE Port
Enable". You will fi nd more information on this and the other setting options
below. If, within 1 hour, the data rate ecxeeds the switch bandwidth limit more than 10x,
the corresponding port is automatically disabled and displayed with a red „OFF".
Undervoltage
Overvoltage
Overheating
etc.