5 Initial Operation
5.3.1

Presentation

Target function
Upper torque
Lower torque
Upper relative torque
Lower relative torque
Angle
Input
Time
Yield point
Gradient
Table 4:
Monitoring function
Torque
Relative torque
Maximum torque value
Minimum torque value
Average torque value
Torque range
Redundancy torque
Tightening from above
Tightening from below
Angle
Total angle
Redundancy angle
Gradient
Average gradient
Time
Stick slip
Yield point
Table 5:
Function
Actual value Display
Total time
tG
Table 6:
Result
Identification
Cancel start signal C(c)w
System error
Fault
Table 7:
Electric Drives and Controls | Bosch Rexroth AG 13/40
Actual value
T
Tl
T&
Tl&
A
In
t
Yield
G
Actual value
T
T&
T>
T<
TA
T[
TR
Tlu
Tll
A
AT
AR
G
GA
t
STS
Yield
Yes/No
Yes
0
The inverse presentation shows:
– Error
– NOK.
5.3.2
Language packs
The language packs for the LTU and the
SD301 are loaded simultaneously into the
control system with the help of the BS300
operating system. This loading is done by us-
ing either the menu item "Configuration | Sys-
tem display" in the BS300 or the firmware
update.
5.4
X2 Interface
This interface acts as a selective supply for
personnel security.
Pin
Assignment
1
external 24 V (out)
2
external 24 V (out)
3
PS (personnel security)
4
PS (personnel security)
5
0 V reference potential
6
0 V reference potential
7
0 V reference potential
8
Motor contactor auxiliary contact for
monitoring (break contact)
9
Motor contactor auxiliary contact for
monitoring (break contact)
10
not assigned
Table 8:
Note:
Pins 2 and 3 are furnished with a
jumper guaranteeing the opera-
tional readiness of the servo am-
plifier.
This jumper must be removed in
order to connect an emergency-
off circuit.

Werbung