Gasoline generator as a power source
CAUTION:
more input voltage than specified in the
voltage range can cause damage to the
product.
A generator that operates on gasoline can be used as a
power source if it can supply sufficient power. Refer to
Technical data on page 17 for typical generator
operation conditions. The generator must be grounded
to prevent damage to the product.
To connect a power source to the product
CAUTION:
to a power source without an applicable
fuse.
1. Connect the power cord from the power source to
the electric socket on the product.
Note:
A 5-pin product with a 1 phase socket (230
V), must have a neutral wire (N) for the electric
socket to operate. The product can be operated
without a neutral wire.
N
PE
2. Use the remote control to select the correct fuse. In
the menu system, select "DRIVE CHOICES" and
then "SET FUSE".
8
A generator that supplies
Do not connect the product
L3
L2
L1
3. Select the correct fuse.
>>>SET FUSE
16A
25A
32A
To connect the water supply
CAUTION:
prevent that dirt causes a blockage in the
water system.
Note:
The water coolant does not stop during a power
failure.
Note:
The product has an electric water valve, which
is closed when the product starts. When the product is
disconnected from the current, the water valve opens to
drain the water coolant. This is to prevent the water
inside the product to freeze.
1. Connect the water hose to the water connector inlet
on the product.
2. Connect the water connector outlet on the product to
the power tool.
3. To adjust the flow of water coolant to the power tool,
refer to the operator's manual for the power tool.