Replacing Seal Belts
Replace the Seal Belts when:
• The film jams frequently.
• The film does not advance with drive motor running.
• The machine is producing very poor seals even after
adjustment of the seal temperature.
1
Turn Power OFF, unplug Power
Cord, then wait 10 minutes for Seal
Bar to cool. Open Belt Cover with
Slotted or Phillips Screwdriver.
3
Push spring-loaded
rollers toward front of
Machine to loosen either
Seal Belt. Remove Seal
Belt and replace it.
Replace both Seal Belts.
Routine Maintenance
Weekly Maintenance:
If necessary, clean the Seal Belts and the Drive Rollers. Warm water and mild detergent are recommended.
Monthly Maintenance: Check the entire MINI PAK'R Machine for damage. Replace worn or damaged parts, if necessary, and/or
contact your distributor.
Table of
Table of
Contents
Contents
2
Lift Belt Release
Lever to loosen
Seal Belts.
4
Tighten Seal Belts by
locking Belt Release
Lever in place.
MINI PAK'R 제조기 사용자 설명서
-16- 페이지
MINI PAK'R Machine User Manual
Display
Error Codes
Display
Error
Code
E1
Cover Open
E2
Jam/end of roll
E3
Temp. too high
E4
Temp. too low
E5
Temp not rising
No roll detected
E6
E8
Thermocouple Error
E9
Invalid Tag Error
Temperature Measurement
E10
Error
E11
Temperature Timeout
Page -16-
MINI PAK'R Machine User Manual
Error Codes
If the Display shows an Error Code, and the red LED flashes, consult the chart below to
determine the cause. Clear the problem as described below then press the STOP/RESET
Button to resume normal operation.
Action
Make sure covers are closed.
In case of jam, open Belt Cover and remove jammed film carefully.
Contact your distributor or Pregis for assistance.
Contact your distributor or Pregis for assistance.
Contact your distributor or Pregis for assistance.
Press STOP/RESET. This may clear the error. If not, Display will show "Sty" (Standby
state). Advance the film slowly at the front of the Machine so the Film Roll rotates. The
display should change to show the seal temperature, and then "rdy" (Ready state). If
the error can't be cleared, contact your distributor or Pregis for assistance.
TC is broken or not connected.
RFID Tag for a different machine is detected.
Initialization Error. Press reset and repower the machine.
Temperature reading initialization timed out.
Page -17-