Herunterladen Inhalt Inhalt Diese Seite drucken

Functional Description - Makita CL070D Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für CL070D:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
FUNCTIONAL
DESCRIPTION
CAUTION:
Always be sure that the tool is switched off and
the battery cartridge is removed before adjust-
ing or checking function on the tool.
Installing or removing battery
cartridge
► Fig.1: 1. Battery cartridge 2. Button
Always switch off the tool before insertion or
removal of the battery cartridge.
To remove the battery cartridge, withdraw it from
the tool while pressing the buttons on both sides
of the cartridge.
To insert the battery cartridge, hold it so that the
battery cartridge front shape fits to that of the
battery installment opening and slip it into place.
Always insert it all the way until it locks in place
with a little click. If not, it may accidentally fall
out of the tool, causing injury to you or someone
around you.
Do not use force when inserting the battery car-
tridge. If the cartridge does not slide in easily, it is
not being inserted correctly.
Switch action
► Fig.2: 1. Switch trigger
CAUTION:
Before inserting the battery cartridge into the
tool, always check to see that the switch trigger
actuates properly and returns to the "OFF"
position when released.
To start the tool, simply pull the switch trigger. Release
the switch trigger to stop.
ASSEMBLY
CAUTION:
Always be sure that the tool is switched off and
the battery cartridge is removed before carrying
out any work on the tool.
Disposing of Dust
CAUTION:
Empty the cleaner before it becomes too full, or
the suction force weakens.
Be sure to empty out the dust inside the cleaner
itself. Failure to do so may cause the filter to be
clogged or the motor to be damaged.
► Fig.3: 1. Capsule 2. Suction inlet
In order to drop dust sticking on the filter in the capsule,
tap the capsule 4 or 5 times with your hand.
► Fig.4: 1. Capsule 2. Suction inlet
Now point suction inlet downwards, turn capsule in
direction of arrow in diagram, and disconnect capsule
slowly and straight.
NOTE:
Dust may spill out when capsule is opened, so
be sure to set a garbage bag beneath capsule.
► Fig.5: 1. Prefilter 2. Capsule
Remove accumulated dust from inside of capsule and
off of prefilter.
► Fig.6: 1. Prefilter 2. Securing lip
Twist prefilter in direction of arrow to unfasten securing
lip from cleaner unit and then pull off prefilter.
► Fig.7: 1. Filter 2. Prefilter
Clean out fine dust from prefilter. Next, remove filter,
and lightly tap to dislodge dust.
Reassembly
► Fig.8: 1. Filter
Put on filter until it is fully in position on the cleaner unit.
NOTE:
Make sure filter is put on straight without being
peeled back. If filter is put on incorrectly as
shown in diagram, dust will get into motor hous-
ing, and cause motor failure.
► Fig.9: 1. Filter
Connect prefilter. At this time, make sure to twist prefil-
ter so that securing lip is firmly locked into cleaner unit.
► Fig.10: 1. Prefilter 2. Securing lip
► Fig.11
Connect capsule. Align projection on capsule with pro-
jection on handle and then firmly twist capsule in direc-
tion of arrow until it is secured.
► Fig.12
► Fig.13: 1. Capsule 2. Handle 3. Projection
NOTE:
Always remove dust ahead of time, as suction
power will be reduced if there is too much dust
in cleaner.
Always be sure to check that both filter and pre-
filter are loaded correctly prior to using cleaner.
If they are not loaded correctly, dust will get into
the motor housing, and cause motor failure.
If the following examples occur, filter and prefil-
ter are not loaded correctly. Reload them cor-
rectly to rectify problem.
Problem Examples
Example 1: Only prefilter has been loaded (no filter)
► Fig.14: 1. Prefilter
Example 2: Only filter has been loaded (no prefilter)
► Fig.15: 1. Filter
Example 3: Filter has been loaded in a peeled back
state
► Fig.16: 1. Filter
8 ENGLISH

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cl100d

Inhaltsverzeichnis