• The device should be mounted in such a way that it de ects 2-5° from the horizontal position towards the
outside. It is prohibited to mount the device in a vertical position (in a ceiling, roof).
Transport and storage
• The device should be stored in an original packaging, in a dry place protected against precipitation.
• The temperature at the place of storing and transport should be maintained between -20°C and +40°C.
• Avoid strokes and surges. The fans should be transported in an original packaging.
• In the case of storing period lasting longer than 1 year, you should check, before mounting, whether the
bearings of the engine function properly by rotating the rotor using your hand.
• The disposal should be carried out in a proper and environmentally sound manner, in accordance with legal
provisions.
• The damages caused by an improper transport, storing or activation should be demonstrated and are not
subject to guarantee.
OPERATION DESCRIPTION AND EQUIPMENT
Operation description:
HRV recuperator is equipped with aluminium regeneration heat exchanger. Recuparation of the heat lost during
the ventilation process is possible due to the duplex direction work of the fan. The device works alternately:
- Exhaust cycle (the heat from the stream of the exhaust air is accumulated in the exchanger),
- Supply cycle (the heat accumulated in the exchanger is emitted to the stream of supplied air).
The time of each cycle is 60 s.
HRV devices are equipped with engines with two rotational speeds. The change in the direction of air ow is
automatic.
Available equipment options:
Standard (index without an additional marking). The models in standard version should be connected in
accordance with connection scheme in the Fig. 3.
The fan is activated with a separate on-switch constituting an element of electric wiring system of a building (it is
not an element of the device). The change of the rotational speed takes place alternately, after subsequent pulls
of the pull switch.
Remote (index ended with "P" letter). The models equipped with a remote should be connected in
accordance with the connection scheme in the Fig. 4.
The fan is activated with the button on the remote (Fig. 2). The change in the rotational speed takes place
directly after pressing the adequate button on the remote. After switching on and switching o again, the
device works based on the gear that has been set the last time.
CONSTRUCTION AND MOUNTING
The basic elements of the device:
1. Two-speed supply-exhaust fan.
2. Aluminium accumulation heat exchanger.
3. Air lter.
4. Telescopic section of air duct, adjustable: 335 - 540 mm.
5. End of the air duct.
6. Remote control (in the case of HRV100P / HRV125P model).
Only trained personnel may, in accordance with the applicable provisions, mount, connect
to power supply and activate the fan!
Mounting process
• Precisely specify the place, where the device is to be installed.
• Prepare power supply cable. Use NYM-O 2x1,5 mm² (H07V-K 2x1,5mm²) with the maximum diameter of 8 mm.
EN